LLLT

Low-level LASER Therapy

Laser therapy, which uses the healing properties of low-intensity laser (of all wavelengths of visible light plus UV and IR), thanks to its unique effectiveness, lack of side effects and contraindications of specific, as well as the simplicity and low cost have long occupied a strong position in modern medicine. Furthermore, the scientific and practical basis for radiotherapy is actively growing, developing new and more effective methods and instruments for their implementation.

Modern laser machines allow us to apply methods of radiotherapy in the treatment of many diseases and pathological conditions, for which until there was no effective treatment.

 

How does LASER work on the body?

Other names for Low-level laser therapy (LLLT) are: cold laser, non-thermal laser, soft laser, biostimulation laser, low-intensity laser, low power laser therapy, etc. Low-level lasers are sometimes used in acupuncture, with the laser beam directed at acupoints instead of the insertion of needles.

  • LASER apparatus from the country that invented the technology
  • Highly efficient and ergonomic equipment
  • Science-based techniques of LASER exposure
Base Unit

Modes of radiation: pulsed or continuous, modulation determined by LASER head
Wavelength: determined by the removable remote transmitter (365-1300 nm)
Pulse repetition rate (Hz)
– Fixed values: 80, 600, 3 000, 10 000
– Arbitrary choice: 0.5-10 000
Timer (automatic)
– Fixed values (min): 1; 10 and “H” (not restricted)
– Arbitrary choice (min): 0.1-90
Average operating time without maintenance: 5,000 h
Range of controlled pulsed radiation power: 2-99 W
Range of controlled average radiation power: 1-250 mW
Power supply: 90-250 V
Maximum power consumption: 14 W
Frequency: 47-65 Hz
Operating temperature range: 10-35 °C
Overall dimensions: 280 x 210 x 105 cm
Weight: 800 g
Safety class: II, type B (ground is not required)
Class of LASER danger: 1M

Used heavy-duty foil keyboard, which guarantees one million clicks on any keyboard button, i.e. more than 20 years of continuous operation of the machine!

ultra-connectors TRS 6.35 mm stereo, manufactured by a unique 3-wire technology LAZMIK, are color differentiation for wavelength that ensures the use of precisely the right laser head

Duplication of double wire each of the three control lines can guarantee the absence of accidental breakage

Imported laser diodes leading manufacturers with continuous operation up to 150,000 hours.

External power supply with certification by European standards for medical devices (EN60601-1) eliminates high voltage in the machine.

Intravenous LASERs

Intravenous LASER Irradiation of Blood

The first flash coverage intravenous laser blood has been applied by EN Meshalkin and VS Sergievskiy (1981) of Russia in cardiac surgery. Longtime research of Russian scientists formed the basis of this procedure which was then developed further and optimized in Germany. The technology which was little known in the West because of decades of political separation, and were regarded with disapproval.

Significantly reduces treatment time, increase the time of remission, stabilization for diseases to reduce the number of postoperative complications

Outpatient laser therapy reduces opportunities for the development of hospital acquired infection, creates a good psycho-emotional background allowing the patient to cooperate for a long time.

Effects of Intravenous  LASER irradiation of blood

  • Stimulation of immune response, specific and non-specific
  • Increase of serum content of  IgG, IgM and IgA
  • Stimulation of interferons, interleukins and TNF-alpha
  • Increase DNA synthesis of lymphocytes, stabilize ratio of subpopulation of T-helper / T-suppressor cells
  • Increase of phagocytic activity of macrophages
  • Lowering of C-reactive protein (CRP)
  • Improvement of the anti-oxidant enzymatic system with antitoxic effect in response to the increase in the content of reactive oxygen species (ROS), detectable when exposed to LLLT across the spectrum
  • Improvement of regeneration of erythrocytes and of microcirculation
  • Reduction of aggregation of thrombocytes
  • Activation of fibrinolysis
  • Stimulation of the NO-production in monocytes with vasodilatation and improvement of endothelial dysfunction
  • Fusion of mitochondria to “giant mitochondria” with increase of ATP-production in the respiratory chain
  • Normalization of the cell membrane potential

 

Intravenous laser blood cleansing is an effective and useful procedure for the entire body. People sit down on a diet to cleanse the body of toxins and excess kilograms, and this happens here. Blood supplies nutrients to all cells and organs, oxygenation of tissues and cells depends on it. The radiators of the intravenous laser head are designed to carry out this cleaning as efficiently as possible.

The procedure of blood irradiation is used in the following fields of medicine: urology and gynecology, endocrinology, gastroenterology and dermatology, pulmonology and cardiology.

The intravenous LASER radiators allow to anesthetize and overcome inflammation, normalize the hormonal background and stimulate the work of the ovaries, mammary glands, adrenals and thyroid gland. In addition, the restoration of damaged tissues passes much faster, including soldering effectively.

Useful properties of radiators
The main feature of blood purification is the strengthening of the protection of the whole organism. That is, it not only cleanses itself of alcoholic, narcotic and exhausted substances, but also becomes healthier.

In addition to blood, other biological fluids pass through the bloodstream: lymph and bile. During the session, there is a restructuring of cell membranes and resorption of loose blood clots, pathogenic microorganisms are destroyed. Blood irradiation is used not only for acute and chronic poisonings, but for various respiratory diseases, helping to breathe again full chest.

 

Fields of Application

(consult for the right intravenous LASER head to use)
Obstetrics and gynecology (purulent-septic complications, female infertility, late toxemia of pregnancy, prevention of postoperative complications, salpingo-oophoritis, fetoplacental insufficiency, endometriosis, endocervicitis) – radiating heads KL-VLOK, KL-VLOK-IC Dermatology (allergic skin vasculitis, angiitis (vasculitis) knotty, atopic dermatitis, herpes simple recurrent, dermatophytosis stop, psoriasis, erysipelas, Lyell’s syndrome, eczema) – KL-VLOK, KL-VLOK-M, KL-VLOK-365, MS- VLOK-530
Diseases of peripheral vessels (atherosclerotic arteriopathy of the lower limbs, diabetic angiopathy of the lower extremities, thrombophlebitis of the lower extremities, chronic ischemia of the lower extremities, chronic obliterating diseases of the arteries of the lower extremities) – CL-VLOK, KL-VLOK-Z65, MS-VLOK-450
Diseases of the digestive system (dysplastic changes in the gastric mucosa, viral hepatitis B, mechanical jaundice, acute intestinal obstruction, acute cholecystitis, poisoning, pancreatitis, hepatic insufficiency, cholangitis, chronic diffuse liver disease, chronic non-ulcerative colitis, chronic cholecystitis, cirrhosis, ulcer disease stomach and duodenum) – KL-VLOK, KL-VLOK-365, KL-VLOK-405
Diseases of the musculoskeletal system (deforming osteoarthritis, rheumatoid arthritis) – KL-VLOK-M, KL-VLOK-365, KL-VLOK-IK
Cardiology (arterial hypertension, myocardial infarction, infectious allergic myocarditis, ischemic heart disease, angina pectoris, acute coronary insufficiency, heart defects, sinus node dysfunction syndrome) – CL-VLOK, KL-VLOK-365, KL-VLOK-532
Neurology (ankylosing spondylitis (Bechterew’s disease), vegetative-vascular dystonia, vibration disease, hypothalamic syndromes, degenerative-dystrophic diseases of the spine, discirculatory encephalopathy, ischemic and traumatic myelopathies, neuroinfection (meningitis and meningoencephalitis), polyneuropathy, postoperative complications, consequences of craniocerebral trauma, prosopathy, radiculoalgic syndrome after discectomy, multiple sclerosis, chronic fatigue syndrome, cerebral stroke, epilepsy IY) – CL-VLOK, KL-VLOK-M, ML-VLOK-365, KL-VLOK-IR, MC-VLOK-450
Oncology – CL-VLOK, KL-VLOK-532, MS-VLOK-530 Otorhinolaryngology (Meniere’s disease, sensorineural hearing loss, tonsillitis) – KL-VLOK, KL-VLOK-IC, KL-VLOK-365
Ophthalmology (diabetic retinopathy, vitreous hemorrhage (hemophthalmus), retinal vein thrombosis) – CL-VLOK, MS-VLOK-530, KL-VLOK-532
Psychiatry (withdrawal syndrome in patients with alcoholism, withdrawal syndrome in patients with addiction, schizophrenia, endogenous psychosis) – KL-VLOK-M, KL-VLOK-365
Pulmonology (lung abscess, bacterial destruction of the lungs, bronchial asthma, bronchoectatic disease, chronic nonspecific lung diseases, chronic obstructive bronchitis, acute pneumonia) – KL-VLOK-M, KL-VLOK-365, KL-VLOK-IC, MS-VLOK- 450
Dentistry (purulent-infectious processes of the maxillofacial region, phlegmon, periodontitis) – CL-VLOK, KL-VLOK-365, KL-VLOK-IK
Urology (secondary amyloidosis of the kidneys, hemodialysis and kidney transplantation, glomerulonephritis, diabetic nephropathy, pyelonephritis, urogenital infection, urethritis, chronic inflammation of the scrotum organs, chronic nonspecific infectious prostatitis, chronic renal failure) – KL-VLOK, KL-VLOK-365, VLOK-405, KL-VLOK-IK
Phthisiology (pulmonary tuberculosis) – KL-VLOK-M, KL-VLOK-365 VLOK in surgical practice (anesthesiology, purulent-inflammatory diseases, purulent-necrotic complications of patients with diabetes mellitus, purulent-septic complications in surgical practice, reimplantation, disseminated intravascular coagulation syndrome (DVS-syndrome), chronic osteomyelitis, burn disease, frostbites) -VLOK, KL-VLOK-M, KL-VLOK-365, KL-VLOK-405, MS-VLOK-450
Endocrinology (autoimmune thyroiditis, hypothyroidism, diabetes mellitus) – KL-VLOK-M, KL-VLOK-365, KL-VLOK-IC, KL-VLOK-532, MS-VLOK-530.

 

CHECK STUDIES AT:

Intravenous LASER Procedure

Effects of IV LASER on DM2

Non-Invasive LASERs

Non-Inasive LASERs

Topical LLLT is the application of visible red or near-infrared light emitted from a low power laser to help heal wounds and to treat many of types of musculoskeletal injuries and disorders including back pain caused by lower back strain, herniated discs, fibromyalgia, etc. Unlike high-power lasers, low-level lasers do not heat or damage human tissue.

Topical LLLT is used to treat both acute and chronic pain. The benefits of low-level laser therapy appear to be accumulative – it may take several treatments for the results to become evident.

Total number of treatments needed depends upon the condition being treated, the severity of the condition, and each patient’s individual response.

Check studies made at:

  • http://www.healinglightseminars.com/articles-2/

Non-Invasive LASER Emitters

Single LASERs Emitters & Nozzles

LASER emitter 635 nm (red), pulsed/continuous, 15 mW, replaces methodologically helium-neon LASERS

Suggested use: acupuncture, local site irradiation

Radiation mode  – continuous, modulated
Radiation wavelength: 635 nm
Radiation power: 10 ± 2 mW
Depth: 2-5 cm
Duty cycle of modulated radiation: 2 ± 0,2
Divergence of the ray in the plane h:  10°
Divergence of the ray in the plane v: 40°

LASER emitter 904 nm (infrared), pulsed/continuous, 20 W

Radiation mode is pulsed
Radiation wavelength:  890-904 nm
Pulse power of radiation:  15-20 W
Depth: 10-15 cm

This universal single laser head with average LASER power when used with pulsed radiation is intended for joint work.

The laser emitting heads of the infrared spectrum of radiation are able to penetrate into the tissues of the body to a great depth of 10-15 cm. This leads to warming of the entire thickness of the skin and part of the subcutaneous tissues. This type of radiation contributes to the elimination of inflammatory processes, accelerates healing, increases local resistance and anti-infective protection. It is used in all fields of medicine.

Acupuncture nozzle
with metal tip A-3 (spot size not more than 1 mm in diameter) is intended for concentration of laser radiation at acupuncture points.

Cosmetic nozzle
intended for cosmetic procedures when gels are necessary and for photophoresis or photodynamic therapy

Mirror nozzle

Designed for the mirror-contact method of action. Extremely versatile and useful: increases the depth and intensity of the therapeutic effect, ensures the stability and reproducibility of the procedure, protects medical personnel from reflected radiation, ensures the hygienic procedure, it makes it easier to calculate the dose, since the effective area of ​​exposure is assumed equal to 1 cm²

LASER Shower Emitters & Nozzles

LASER shower emitter, 635 nm, pulsed, 40 W

for non-invasive techniques (topical, transdermal), non-invasive LASER flash coverage blood, use on bioactive or reflex zones

Radiation wavelength: 635 nm
Maximum radiation power over the entire surface: 40 W
Depth: 5 cm
Number of diodes: 8
Area irradiated: 8-50 cm2 (the area is calculated at a distance of 0.5 to 7 cm limit)
The area of the irradiated surface at a distance of 1 cm from the exit window: at least 30 cm2

NOTE: The power is measured only when the protective cover is closed, according to the LED scale on the rear panel. The power output auto adjusts depending on the distance of the diodes to the surface

It is used in all fields of medicine. Replaces intravenous blood clotting. Non-invasive blood coverage. Used in Pediatrics

Effects on the Bioactive zones (dermatomes): Influence on the projection of internal organs: Urology, Obstetrics and Gynecology, Otorhinolaryngology, etc.

LASER shower head, 904 nm, pulsed, 80 W

for non-invasive exposure of internal organs, laser flash coverage blood, use on bioactive or reflex zones

Radiation wavelength: 904 nm
Maximum radiation power over the entire surface: 80 W
Depth: 15 cm
Number of diodes: 8 (diodes are direct, no glass cover)
Area irradiated: 8-50 cm2 (the area is calculated at a distance of 0.5 to 7 cm (limit)
The area of the irradiated surface at a distance of 1 cm from the exit window: 20 cm²
Weight: 0.35 kg
Overall dimensions (with packing): 22 х 6 х 9 cm

Note: power output auto adjusts depending on the distance of the diodes to the surface

This infrared LASER shower head is the most universal and should fit into almost every set. It is a matrix of 8 infrared pulsed laser diodes with radiation power control. Power is measured when the protective cover is closed. The power value is displayed on the LED scale at the back.

Cap for LASER shower head

Medical grade colorless plastic intended for joint work with LASER shower heads. The nozzle is used to work on the surface, providing contact with the skin. It does not reduce the effect of the LASER and acts as protection for diodes of LASER shower emitter especially if gels and creams are to be applied for photophoresis or photodynamic therapy and cosmetologic applications.

Magnetic nozzle for LASER shower head

Enhances effectivity of LASER therapy especially for joints and internal organs. The magnetic induction of 50 mT that increases the depth and intensity of the therapeutic effect, ensure the stability and reproducibility of the procedure

Contact Us

We're not around right now. But you can send us an email and we'll get back to you, asap.

Not readable? Change text.

Start typing and press Enter to search